Grupo: Analytik Jena
Extractos del catálogo
analytikjena An Endress+Hauser Company
Abrir la página 1 del catálogoAnalytik Jena has a long tradition in developing high quality and precisión analytical systems which dates back to the inventions made by Ernst Abbe and Carl Zeiss. Today Analytik Jena is a leading manufacturer of high performance analytical instruments and one of the most innovative companies. 1924 First Pulfrich photometer - the basis for the development of spectrophotometry in Jena 1937 First flame photometer - Carl Zeiss establishes the methodology of flame photometry 1963 SPEKOL® and SPECORD® update the tradition of Pulfrich photometers in Jena 1969 Prototype of the first...
Abrir la página 2 del catálogoRecent Technologies Translated into a Family of Instruments that Sets Standards Decades of experience in the development of spectrometers, plus the most recent findings made in electronics and furnace design, have gone into the novAA® series. Transverse-heated graphite furnace The future-oriented furnace heating concept, which can cope with a variety of samples, including complex matrices and refractory elements. Automation has never been more convincing Flexibility and efficiency, requirements in fully automatic sample preparation, are provided by AS-F, AS-FD and AS-GF, intelligent...
Abrir la página 4 del catálogoA Match for Every Requirement Variable sample feeding techniques This is unique: Smooth feeding of liquids and solids (direct analysis), and fast change between both techniques. ASpect LS data analysis and control software A convincing software concept that is not only efficient for laboratory routine but also gives the user every freedom for method development and optimization. Analytical quality assurance and validation feature greatly in this product. Long high-performance life guaranteed for 10 years Quartz coated optics and encapsulation guard against corrosive laboratory atmospheres...
Abrir la página 5 del catálogoTransverse-Heated Graphite Furnace -State-of-the-Art Technology The transverse-heated graphite furnace is a must where optimum atomization conditions and high sample throughput are required simultaneously. A unique furnace design The clearly superior concept of the transverse-heated graphite furnace has, for a number of years, been successfully employed in all Analytik Jena graphite furnace AAS systems. It guarantees uniform temperatura all along the optical axis throughout the tube and eliminates memory and condensation effects that occur at the cooler tube ends of conventional,...
Abrir la página 6 del catálogonovAA® 400P with solid sampler SSA 600 Sample tray for up to 84 samples Liquid dosing accessory solid AA® – Direct Analysis of Solids. Intelligent Innovation Pushes Back Limits Two different feeding systems for solid samples are available: SSA 6 z – manual solid sampler Manual module for the reproducible insertion and removal of the sample carrier. Even with external manual weighing, automatic data transfer is made via the ASpect LS software. SSA 600 – automatic solid sampler with integrated microbalance This system allows routine solid AAS. Not only transport of the loaded sample carrier...
Abrir la página 7 del catálogoEfficiency and Productivity Feature Greatly In today´s laboratories, automation of the AA flame mode is more important than ever. Fast analysis, automated dilution, reliable quality monitoring, all with uncomplicated handling, are a must. Meeting these requirements with ease, the novAA® series is bound to become an indispensable routine spectrometer for element analysis. Flame autosampler – Maximum sample throughput and automatic dilution Autosamplers for the flame mode make your routine analysis of standards and samples almost fully automatic. Integrated in the overall concept of the...
Abrir la página 8 del catálogonovAA® 400P with graphite furnace autosampler novAA® 350 with hydride system Unique Technique to Analyze Hydride-forming Elements Mercury and hydride analysis – multiple solutions for special challenges The measurement and monitoring of mercury and such elements as arsenic or selenium down to low ppb concentrations has always been a challenge. In order to keep the amount of these toxic substances under control in the environment, fast methods and convenient, yet flexible systems are required. The availabilitiy of flow injection and batch mode at the various automation levels guarantees...
Abrir la página 9 del catálogoASpect LS – Clearly Structured and Flexible Completely automated optimization of the parameters Great emphasis is placed on innovative functionality when developing devices. Fully automatic routines optimize the analysis process and thus also guarantee the optimum conditions at high sample throughput and therefore the maximum reliability of the results. Pyrolysis and atomization temperatures are changed using the „Optimization of the furnace parameters“ software function and adapted to the respective application. Advanced user-friendliness Simple, routine handling on one hand, great...
Abrir la página 10 del catálogoQuality control and GLP In view of today‘s statutory and in-house requirements, comprehensive quality assurance is a prime consideration implemented in the AAS software. Compliance with these requirements can be assured: ■■ Keeping different control charts for statistical quality control ■■ Various responses when error limits are exceeded or warning levels reached ■■ Automatic instrument functionality test ■■ Data recording and printout conforming to GLP FDA 21 CFR Part 11 Conformity to FDA 21 CFR Part 11 is a must for modern analysis software. The functions integrated in ASpect® LS ensure...
Abrir la página 11 del catálogoAnalytik Jena AG Pictures: Analytik Jena AG Konrad-Zuse-Str. 1 Subjects to changes in design and scope of delivery as well as further technical development! en■09/2016■888-11001-2 Forster & Borries GmbH & Co. KG © Analytik Jena AG
Abrir la página 12 del catálogoTodos los catálogos y folletos técnicos Analytik Jena GmbH+Co. KG
-
multi X 2500
12 Páginas
-
UVP GelSolo
8 Páginas
-
CyBio QuadPrint
3 Páginas
-
qTOWER3 Product Family
20 Páginas
-
contrAA800
8 Páginas
-
Product Overview Chemical Analysis
24 Páginas
-
Quality is the Difference
16 Páginas
-
The Dedicated Mercury Trace Analyzer
8 Páginas
-
multi N/C
16 Páginas
-
novAA800
12 Páginas
-
compEAct
8 Páginas
-
PlasmaQuant MS
12 Páginas
-
PlasmaQuant® MS
12 Páginas
Catálogos archivados
-
SPECORD PLUS
16 Páginas
-
multi N/C
24 Páginas
-
multi EA 5000
20 Páginas
-
multi EA 4000
12 Páginas
-
ZEEnit P Series
16 Páginas
-
TOPwave
8 Páginas
-
Flyer UV/Vis Validation
2 Páginas
-
Flyer TOPwave RTM
2 Páginas
-
Flyer TOPwave RPM
2 Páginas
-
Brochure mercur
8 Páginas
-
Flyer PlasmaQuant PQ 9000
2 Páginas
-
Brochure PlasmaQuant PQ 9000
12 Páginas
-
Brochure solid AA
16 Páginas
-
Brochure contrAA series (English)
20 Páginas
-
Product catalog total
372 Páginas