1. Catálogos
  2. JULABO GmbH
  3. F-gas Regulation
video corpo

F-gas Regulation

F-gas Regulation

Resumen del catálogo de productos
Regulación de Gases Fluorados (F-gas)
Introducción: La Regulación de Gases Fluorados es una normativa de la UE destinada a controlar los sistemas que contienen hidrofluorocarbonos (HFCs), gases que contribuyen al calentamiento global. Esta regulación, vigente desde el 1 de enero de 2015, exige el registro y revisión periódica de sistemas como unidades de aire acondicionado y refrigeración.
Contenido Específico:
  • Hasta el 31.12.2016: Sistemas con menos de 3 kg de gases fluorados o sistemas herméticamente sellados con menos de 6 kg no requieren pruebas de fugas.
  • Desde el 1.1.2017: Sistemas con equivalencia de CO2 entre 5 y 50 toneladas requieren una prueba de fugas anual, responsabilidad del operador.
  • Desde el 1.1.2020: Prohibido el uso de refrigerantes con GWP mayor a 2500 en sistemas donde la temperatura mínima es mayor a -50 °C.
Validez: La regulación es válida en todos los países de la UE y todos los productos vendidos deben cumplirla.
Gases Fluorados: Son gases sintéticos que pueden permanecer en la atmósfera durante siglos, contribuyendo al calentamiento global. Los HFCs son los más comunes y se utilizan en refrigeración, sistemas de aire acondicionado, entre otros.
Objetivo de la Regulación: Limitar el aumento de la temperatura mundial a 2 °C y reducir las emisiones de CO2 en un 73% de 1990 a 2030.
Actividades de JULABO:
  • Reparaciones y pruebas de fugas: Personal capacitado para realizar reparaciones y pruebas de fugas con altos estándares ambientales.
  • Nuevos productos: Cumplen con la regulación y utilizan refrigerantes compatibles.
  • Seguridad: Los productos utilizan refrigerantes seguros para el usuario.
Servicio JULABO:
  • Pruebas de fugas: Ingenieros certificados realizan pruebas anuales, tanto in situ como en instalaciones de JULABO.
  • Mantenimiento y reparación: Los productos pueden ser mantenidos y reparados después de 2020 con especificaciones consistentes.
  • Contratos de mantenimiento: Ofrecen tiempo de inactividad mínimo y máxima seguridad.
Preguntas Frecuentes:
  • Pruebas de fugas: Requeridas para sistemas con equivalencia de CO2 entre 5 y 50 toneladas cada 12 meses.
  • Mantenimiento post-2020: Los productos JULABO no se ven afectados por las restricciones de 2020 y pueden ser mantenidos.
  • Uso de propano: No se utiliza debido a su inflamabilidad y restricciones de transporte.
  • Productos cubiertos: Unidades de refrigeración que usan refrigerantes con GWP > 2500.
  • Definiciones: GWP mide el efecto relativo de un compuesto en el calentamiento global; equivalencia de CO2 es el producto del GWP por el volumen de llenado.
Ver más

Extractos del catálogo

F-gas Regulation-1

F-gas Regulation JULABO Guide

 Abrir la página 1 del catálogo
F-gas Regulation-2

What is the F-gas Regulation? The F-gas Regulation is an EU regulation to control systems containing specific greenhouse stimulating hydrofluorocarbons (HFCs). The new F-gas Regulation was published on June 9th, 2014 and has been effective since January 1st, 2015. The regulation governs that systems such as air conditioning and refrigeration units and fire extinguishing systems using certain gases must be logged and checked periodically for leakage. The new F-gas Regulation does not show filling volumes in kg but assesses the refrigerants according to their Global Warming Potential (GWP). Specific...

 Abrir la página 2 del catálogo
F-gas Regulation-3

JULABO Activities Repairs and leakage tests by JULABO specialists JULABO service personnel have been trained for many years according to (EG) No. 303/2008 and are therefore qualified to perform repairs and leakage tests with the highest environmental standards. New JULABO products fulfill the F-gas Regulation New developments by JULABO will fulfill the F-gas Regulation and use compliant refrigerants. JULABO products meet the highest safety standards User safety is extremely important for JULABO. Precisely for this reason JULABO products use only the safest possible refrigerants. JULABO Service...

 Abrir la página 3 del catálogo
F-gas Regulation-4

FAQ F-gas Regulation When is it required to do a leakage test? Systems using a refrigerant with CO2-equivalence between 5 tons and 50 tons require a leakage test every 12 months. This test has to be ensured by the operator of the system. Is it possible to repair and maintain JULABO products after the year 2020? The filling volume of all JULABO products lies below the 40 tons CO2-equivalent (10.2 kg R404A) which marks the maximum permissible value effective in the year 2020. Subsequently JULABO products are not affected and can be repaired and maintained with consistence performance specification....

 Abrir la página 4 del catálogo

Todos los catálogos y folletos técnicos JULABO GmbH

  1. MAGIO MS-1200FW

    5  Páginas

  2. MAGIO MS-600F

    7  Páginas

  3. F12-ED

    2  Páginas

  4. PURA 22 Brochure en

    12  Páginas

  5. PURA 30 Brochure en

    12  Páginas

  6. PURA 14 Brochure en

    12  Páginas

  7. JULABO Brochure EN

    178  Páginas

  8. PRESTO W56 Flyer

    2  Páginas

  9. Wireless TEMP

    24  Páginas

  10. Booster Pump

    2  Páginas

  11. PRODUCT PORTFOLIO

    28  Páginas

  12. PURA Water Baths

    12  Páginas

  13. JULABO Products

    28  Páginas

  14. JULABO PRESTO W55

    2  Páginas

  15. F34-MA

    2  Páginas

  16. CORIO CD-1000F

    4  Páginas

  17. Julabo SemiChiller

    3  Páginas

  18. JULABO Water Baths

    8  Páginas

  19. ED-13A

    2  Páginas

* Los precios no incluyen impuestos, gastos de entrega ni derechos de exportación. Tampoco incluyen gastos de instalación o de puesta en marcha. Los precios se dan a título indicativo y pueden cambiar en función del país, del coste de las materias primas y de los tipos de cambio.