Extractos del catálogo
HUMAN HEALTH ENVIRONMENTAL HEALTH Atomic Absorption Spectrometers
Abrir la página 1 del catálogoEASY DESIGN Whether you choose the AAnalyst™ 200 or AAnalyst 400, you’ll discover an easy, affordable and reliable flame atomic absorption (AA) solution. We’ve simplified the process of AA analysis—from sample introduction to results. We’ve made it easy for anyone with a basic understanding of atomic absorption to get fast, reliable results every time. And we’ve made the quality and reliability of PerkinElmer available to everyone with these affordable systems. True double-beam Echelle optics combined with the power of a solid-state detector deliver performance not typically available with...
Abrir la página 3 del catálogoTOUGHEST MATRICES From state-of-the-art laboratories to remote mining locations, the AAnalyst 200/400 ensures dependable operation no matter what the location or application. The optical compartment can be purged to provide a protective environment to shield the optical components from corrosive and extremely dirty environments, ensuring optimum performance. The PerkinElmer burner assembly is equally user-friendly. Our corrosion-resistant solid titanium burner heads install easily, while a fail-safe mechanism ensures they’re properly restrained—without hold-down cables. No tools are...
Abrir la página 4 del catálogoWorry-free sampling Our completely inert spray chamber provides superior performance for analysis of corrosive and high-solid matrices. The spray chamber is manufactured from a high-strength composite, eliminating the need for pressure-relief devices. The high-precision nebulizer maximizes stability and sensitivity, even for the toughest matrices and is adjustable so a wide variety of sample matrices—aqueous or organic, acids or bases, diluted or concentrated—can be analyzed under optimum conditions. Whatever your application, the AAnalyst 200/400 provides trouble-free operation. Safety...
Abrir la página 5 del catálogoAANALYST 200 THE FLEXIBILITY TO JUST TOUCH PerkinElmer has brought a new level of flexibility and simplicity to flame AA. Forget hard-to-read, small monochrome or numeric displays with little real information. Our large, color LCD touch screen puts AA analysis at your fingertips, literally. Simply touch the screen to choose operating parameters and you’re on your way. Leveraging the power of Microsoft ® Windows CE®, our touch screen provides many features never before available on low-cost AA systems. Running samples has never been easier. Other highlights of the AAnalyst 200 software...
Abrir la página 6 del catálogoThe AAnalyst 200 instantly recognizes PerkinElmer's cableless Lumina HCL lamps and their operating parameters. The lamp is also automatically aligned in the built-in turret. Simply touch the flame-ignite button, recall a stored method (or use the built-in cookbook to set up a new one) and start the analysis Select up to eight calibration standards and seven different calibration algorithms. Analyze samples manually or fully automate your run with a PerkinElmer autosampler. Even switch to our patented electrodeless discharge lamps (EDLs) that provide much higher light output and longer life...
Abrir la página 7 del catálogoWhen you step up to the AAnalyst 400, you get a reliable, trouble-free flame atomic absorption solution flexible enough to meet the challenges of the most routine analyses and the most demanding applications. The instrument’s robust WinLab32 software combines ease-of-use with greater flexibility to provide an even higher level of productivity. Designed with extensive input from lab managers and AA users around the world, the AAnalyst 400 provides all the tools and features needed to quickly start running samples and meet the needs of today’s laboratory. Extensive wizards make complex tasks...
Abrir la página 8 del catálogoMeet regulated laboratory requirements Many laboratories must comply with a variety of regulations imposed by government agencies or quality protocols Winl_ab32 software can help. Leveraging the powerful security features of Microsoft® Windows®, Winl_ab32 software provides the protection your laboratory needs. It allows the administrator to define groups and assign permission levels using password-controlled access. Once an analysis is completed, a copy of the method is stored with the results and the software "signs" its data during storage. This ensures any alteration is readily detected...
Abrir la página 9 del catálogoCustomize your system Customize your AA system to improve productivity with these simple plug-in accessories that are automatically recognized by the instrument when it is turned on: MHS-15 Mercury/Hydride Analysis System—adapt your system for high-sensitivity determinations of mercury and hydrideforming elements, such as arsenic and selenium: • Detection limits down to the ng range Flow Injection for Atomic Spectroscopy (FIAS) Systems— combine the advantages of mercury/hydride AA with flow injection: • True automation • Exceptional detection limits S10 Flame Autosampler—turn your...
Abrir la página 10 del catálogothat deliver exceptional PerkinElmer atomic absorption (AA) consumables are designed specifically to maximize the performance of our instruments and systems. We validate and test them to ensure you receive accurate, repeatable results, on-time, every time. We have over 50 years’ experience designing and manufacturing the highest performance lamps and offer a full range of single and multi-element hollow cathode lamps and high-intensity electrodeless discharge lamps for those elements for which they are more effective. Graphite Tubes Rely on PerkinElmer graphite tubes and contacts for...
Abrir la página 11 del catálogoOneSource® Laboratory Services is the industry's only audit-proven solution for your entire lab's IQ, OQ and PQ protocols, covering all laboratory technologies and equipment manufacturers worldwide. PE ACE~OF~M I N D ^ years °^ exPenence developing and delivering multi- vendor qualification services and more than 100,000 instrument qualifications completed, we've had zero audits or warnings. And yet, our quality doesn't cost more. In fact, you'll see guaranteed cost savings by consolidating service providers and leveraging economies of scale. With a OneSource service contract, you'll enjoy:...
Abrir la página 12 del catálogoTodos los catálogos y folletos técnicos PerkinElmer
-
Cannabis Testing Solutions
12 Páginas
-
STA 8000
4 Páginas
-
ScanRI
2 Páginas
-
Thermal Analysis
3 Páginas
-
Ultra Clean Gas Filters
10 Páginas
-
NexION® 2000 ICP Mass Spectrometer
12 Páginas
-
TurboMatrix
8 Páginas
-
Clarus® 590/690 GC Systems
8 Páginas
-
NexION® 1000 ICP Mass Spectrometer
8 Páginas
-
Titan MPS Microwave
4 Páginas
-
PinAAcle 500
8 Páginas
-
2400 Series II CHNS/O Elemental Analysis
12 Páginas
-
TurboMatrix
8 Páginas
-
Clarus Gas Chromatographs Brochure
12 Páginas
-
Flexar SQ 300 MS Brochure
8 Páginas
-
Spectrum 10 Spectroscopy Software
6 Páginas
-
SMS 100 Mercury Analyzer Brochure
6 Páginas
-
Atomax Brochure
2 Páginas
-
The PerkinElmer AD 6000 Autobalance
6 Páginas
-
NexION 350 ICP-MS Brochure
12 Páginas
-
Ultra Clean Gas Filters Catalog
10 Páginas
-
AxION iQT GC/MS/MS
4 Páginas
-
AxION 2 TOF
8 Páginas
-
AxION Solo/Xpo Call Out Sheet
2 Páginas
-
AxION DSA
8 Páginas
-
AxION eDoor SQ
2 Páginas
-
Flexar SQ 300 MS
8 Páginas
-
Flexar PDA Plus Detector
2 Páginas
-
NexION 300X ICP-MS Specifications
2 Páginas
-
NexION 300 ICP-MS Brochure
12 Páginas
-
The FilterMate Universal Harvester
4 Páginas
-
EnSpire Multimode Plate Reader
4 Páginas
-
XRD Detector Series
2 Páginas
-
Digital X-ray Flat Panel Detectors
2 Páginas
Catálogos archivados
-
FLEXAR™ Liquid Chromatography
12 Páginas